Cyber Suite LED Keypad Manuel d'utilisateur Page 92

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 120
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 91
Cyber Control 2 VI External Control & Triggering
You can connect up to 255 buttons by combining the 8 ports in binary.
For example, if ports 1, 2 and 3 are connected to the ground pin, this will trigger address 7.
One way of combining the ports from a dry contact switch would be to insert a diode between the switch
and the ports. A generic purpose diode for small signals can be used such as the 1n4148.
Once the port connections have been set up. They can be assigned to trigger a scene within the scene
settings "Trigger" tab. If you are addressing the ports in binary, be sure to select "Address 8" for
example, instead of "Port 8".
You can also set up a port trigger from the previous/next buttons mounted on the interface.
Page 88
Vue de la page 91
1 2 ... 87 88 89 90 91 92 93 94 95 96 97 ... 119 120

Commentaires sur ces manuels

Pas de commentaire